Article number: G3052
The flux is applied to root side before welding and protects against oxidation, which occurs during welding. TA Flux is specially developed for use in connection with GTAW-welding of low-alloy and stainless steel with a maximum 25% nickel content but can also be used with other methods. TA Flux should not be seen as a substitute for protective gas but rather is used where protective gas cannot be used. TA Flux gives a much better weld than without root-protector, but doesn’t quite achieve the qualities of an argon-protected weld.
Testing (ASTM G48) revealed the following technical data:
Loss of weight with argon-protection = 100%
(100%=the loss of weight which occurs with argon-protection)
Loss of weight with TA Flux = 180%
(much better than without root-protection but not as good as argon-protection)
Loss of weight without weld-protection = 318%
Sold in cans of 500 grams
Packaging 4 pcs